Accuracy Pro User Manual

Download the app

Download & install the ONEOF Accuracy App for Windows. The minimum requirements are:

  • Windows 10 version 1803 or more
  • 64 bits
  • Processor Intel i5 or more
  • 4Gb RAM or more

Note: The Accuracy Pro is also compatible with the iOS ONEOF apps.

Plug the device

Plug the USB type-C cable in the device.
The connector is located along the stand.
Note: Always use high-quality shielded USB cables only.

Prepare the watch

If the watch is equipped with a screw-down system, always unlock the crown. Otherwise the signal could be too weak to be correctly processed. Fully wind the watch.

Place the watch

Hold the linear slide and place the watch on the device. The crown should lay on the fine brushed aluminum part. Note: The crown in contact with the sensor always gives the best signal quality.

For heavy watches

You can secure the watch by placing the dedicated rubber around the slide and the sensor cap. You will find two rubbers under the stand of the device.

Plug & play

Start the ONEOF app and plug the device in the computer. Windows will install and configure the device automatically. After a few seconds, the Accuracy Pro icon will appear on the left menu. The device is ready for the first measurement!

UP

App overview

At a glance

The ONEOF Accuracy app window is organized into different areas, menu and bars. The main window is dedicated to the measurement results. The measurement parameters are always readily available through a sliding menu. The app is responsive and tactile (compatible with tablets).

  • Main menu: Navigate through all the plugged devices, the measurement results and parameters databases.
  • Control bar: Includes the buttons to navigate through the different measurement displays, to activate / deactivate the speaker / recorder mode or to export / save the data.
  • Status bar: Shows the current status of the measurement, the frequency of the watch and the quality of the signal.
  • Sliding parameters menu: Includes all the measurement parameters, a list to access a user parameters, the display options, the current device orientation and serial number.
  • Measurement area: Where all the measurements results are displayed.

The measurement windows

The main measurement results – the rate accuracy, the beat error and the amplitude – are always readily available at the top of the main window. The control bar left buttons navigate through different displays: the diagram, the scope, the graphs, the dispersion, the tabular data and the radar chart (multi-position). The navigation is also possible through the two arrows located on the left and on the right of the window.

Diagram

Scope

Dispersion

Graphs

Multi-position

The parameters menu

The measurement parameters are always available through a sliding menu located on the right of the window. It includes a list with the saved user parameters, the current measurement settings, the time management, the display options and the device orientation and serial number.

UP

Performing a measurement

The measurement states

The app has no start / stop button: the measurement starts automatically as soon as a watch is detected on the sensor. When a watch is detected, the measurement goes through different states depending on the set parameters:

  • Detecting frequency (if set automatic)
  • Stabilizing (if non-zero)
  • Integrating
  • Measuring
  • Finished or Failed

The current state is displayed at the bottom left of the window with its full name and optionally a countdown.

The frequency detection

By default, the beating frequency of the watch is automatically detected in one second. When detected, the value appears at the center of the status bar (bottom of the window). It is displayed in both Hertz [Hz] and beats-per-hour [b/h] units.

The diagram display

As soon as the frequency is detected, the diagram starts displaying the results. Each dot represents a tick or a tock over time which results in the shape of two lines.

  • If the watch tends to run faster, the slopes are positive.
  • If the watch tends to run slower, the slopes are negative.
  • If the watch is perfectly accurate, the chart displays flat lines.

In case the watch has no beat error, the two lines are superimposed. If the beat error is greater than 0.0ms, the lines are spaced. The bigger the beat error, the larger the space between the lines.

When the orientation of the device is changed, the app keeps a history of the diagram for each common orientations (CH, CB, 9H, 6H, 3H, 12H).

The diagram display is historically and commonly used by all the watchmakers as it gives a straight visual results of the watch behavior.

Stable & accurate watch running slightly faster with low beat error.

Watch gaining hundreds of seconds per day. Might be magnetized.

Inaccurate vintage watch or noisy environment. Check the gain, increase the integration time for a better rate stability result.

The scope display

The scope is the graphic display of the ticking signal of the watch movement. From the scope, expert watchmakers can detect problems in the escapement phase. It is also a very useful tool to determine if the coming signal is good enough for a correct measurement of the watch.

The Swiss lever escapement is composed of 3 distinctive pulses. The first pulse is temporally very precise and therefore it is used for the computation of the rate accuracy and the beat error. The second pulse is very irregular and cannot be used. The third and most powerful pulse is used to estimate the amplitude of the balance wheel.

Below the main scope view, the app displays the last 6 beating noises. They are automatically refreshed, starting from the left to the right.

The main results

When the integration time is over, the state switches to Measuring and the measurement results are displayed at the top of the measurement area. The rate accuracy is displayed in seconds per day [s/d] at the center, the beat error in milliseconds [ms] on the left and the amplitude in degrees [°] on the right. Each of these values are updated every second.

When the first results are available, a time counter starts and is displayed at the center of the control bar.
Note: In case the user set a specific measurement time (infinite by default), the time counter is displayed as a countdown until the measurement stops.

The graphs

Every second, a new value of both the accuracy and the amplitude is added to cumulative graphs.
It is always interesting to check how these two values vary over time.
Some particular and natural fluctuations might appear, like the impact of defects in the gear train, the drop of the amplitude during the change date, or more generally the variation of the rate accuracy over the entire power reserve of the watch.

The dispersion display

The dispersion display mode represents the stability of both the rate accuracy (on top) and the amplitude (at the bottom) over time. The average and the standard deviation values are computed every second.
Two bar graphs display a clear representation of the variation:

  • The upper slider is the instantaneous value.
  • The lower slider is the average value over time.
  • The grey bars, growing over time, represents the distribution of the results.

The multi-position display

This page summarizes the multi-position testing results in two different mode : the tabular data and the radar chart. The positions follow the ISO 3158 (NIHS 95-10) standard, coming from French abbreviations:

  • CH = “Cadran Haut” = Dial pointing Up
  • CB = “Cadran Bas” = Dial pointing down
  • 9H = “9h Haut” = 9.00 pointing Up
  • 6H = “6h Haut” = 6.00 pointing Up
  • 3H = “3h Haut” = 3.00 pointing Up
  • 12H = “12h Haut” = 12.00 pointing Up
The tabular data
The radar chart

UP

Saving & Exporting

The databases

Measurement results can be easily saved in dedicated databases. Two different databases are implemented in the Accuracy app: local or remote.
The local database runs under Microsoft SQL Server Compact 4.0.
The remote database is compatible with Microsoft SQL Server.
Both databases have the same architecture.
Note: The local and remote databases are not synchronized. It means that a measurement saved in one database will not be automatically saved in the other one.

One watch can have several measurement results. A watch is defined by different fields. Only a name must be filled in. All other fields can stay empty:

 

  • Name
  • Brand
  • Series
  • Type
  • Caliber
  • Reference
In the database, a measurement result is displayed either with the radar chart mode or the tabular mode.
By clicking on a measurement result, the user retrieves all the other results:

 

  • Graphs
  • Dispersion
  • Tabular & radar chart

Saving data

The save button is located on the control bar (top-right of the window).
Measurement results can be saved anytime during the measurement or at the end of a measurement (in case the user set a specific measurement time).
A pop-up appears in which the user can either select a watch (if already created) or create a new one.
When done, the measurements results are automatically added to the watch data.

Exporting data

The export buttons are located on the control bar (top-right of the window).
The data can be exported from a saved measurement or directly from a running measurement (without stopping it).
There are 3 different possibilities for data export:

  • CSV (XLS) file: Raw measurement result – duration, accuracy, amplitude – per second with the watch information and the beat error in the header (if coming from a saved measurement).
  • Light PDF report: Contains the measurement information and the tabular data.
  • Detailed PDF report: Contains all the measurement information, the tabular data, the radar chart and the graphs.

UP

The parameters

The parameters menu

The measurement parameters are always available through a sliding menu located on the right of the window. It includes a list with the saved user parameters, the current measurement settings, the time management, the display options and the device orientation and serial number.

The measurement parameters

The Lift Angle
The Frequency
The Gain

The time management

The Integration Time
The Stabilization Time
The Measurement Time

The warning limits

This display option highlights all measurement result values in red (accuracy, amplitude or beat error) when they are out of the range set by the user.

The parameters database

Just like the results, the measurement and time parameters can be easily saved in both the local or the remote database.
Note: The local and remote databases are not synchronized. It means that a parameter saved in one database will not be automatically saved in the other one.